Azienda | Sedi | Referenze | Qualità | Contatti | Cataloghi | Home
 

PRODUCTS & SERVICES
 » novec 1230 system
 » fire extinguishers
 » recovering halon
 » fire prevention systems
 » fire protection
 » door fan test
 » clean agent testing
 » technician training
 » room integrity testing
 » large building testing
 » residential home testing
 » specialized applications
 » cold fire
 » motormax
 » fire barrier doors
 » signage and posters
 » training courses
 » servicing & maintenance
 » software & utility
CLEAN AGENTS
 » clean agent extinguisher
 » purchase clean agents
 » halon alternative
 » disposal cfc/hcfc/hfc
 » clean agents faq
MARINE FIRE SOLUTIONS
 » marine fire protection
 » ship halon phase out
 » ship halon alternative
 » replacing halon with
    novec 1230
 » replacing halon with
    fm-200
RESERVED TO
 » professionals
 » companies
 » public agencies
 » schools
DEEPENINGS
 » fire suppression system
 » fire extinguisher
 » fire safety
 » halon
 » inergen
 » hfc 23
 » hfc 227
 » fm-200
 » argon




Door fan test: room integrity testing
 

Environmentally friendly
Fire fighting systems designed and produced by Gielle Fire Systems are renowned for their reliability. However, there is a factor which is beyond the control of Gielle engineers that is one of the most common causes for the failure of a system; the ‘Integrity’ of the protected room, i.e. its capacity to hold gas.

Very little disruption
Prior to 1989 discharge testing was the only practical way to prove the ability of the protected room to hold the gas. Today, the environmentally friendly option of Integrity Testing is the accepted method. Both NFPA 2001 and 12A require an enclosure integrity test as part of the acceptance procedure for all clean agent systems. 

Does not interfere with extinguishing system
As well as being environmentally sound, Integrity Testing has several other advantages over the discharge test:

- It causes very little disruption to the working day, since unlike the discharge test, it does not require the tested area to be cleared, and the total expected running time of the test is approximately 4 hours

- The service is repeatable, allowing the room to be tested at any time, for example, if any changes are to be made to the protected area. It is recommended by the EPA, IRI, FM, other insurers, fire suppression equipment manufacturers and the FSSA that such tests should be repeated annually or after any building work.

- It is versatile. Neither the type of the gaseous fire fighting agent, nor the original provider of
the extinguishing system inhibits this vital service.

No system discharge required
Integrity Testing is vital, especially if as a company you have, or are due to decommission your Halon system. New clean agents have less tolerance for leakage than Halon systems. Halon protected rooms could lose over 50% of agent concentration before the fire could re-ignite. The new agents are more critical and can normally only lose about 20% before re-ignition. Therefore, what was an adequately sealed protected area for the use of Halon, would not be adequately sealed for the use of a new agent. 

HOW IT WORKS:
For any gaseous fire suppression installation to be effective, the design concentration must first be achieved, and then maintained at suitable levels within the risk. In order to achieve this the protected area must be adequately sealed around its boundary. Integrity Testing calculates the leak-tightness of a room and predicts how long it takes for the interface between the extinguishing agent and the air to descend to a given level. 

The test equipment comprises of variable speed fans, expandable door panels, pressure gauges and a dedicated portable computer. The door fan unit is fitted into a doorway of the protected area by means of the expandable door panels designed to fit most door frame sizes, and measures the size of holes in the enclosure and the pressures that may exist across them.

The fan speed is adjusted to obtain a steady pressure between the test area and the volume surrounding the test area (equivalent to the column weight exerted by the extinguishing agent following a discharge). This pressure is then maintained whilst readings are taken from pressure gauges.

The measured rate of air input needed to maintain this pressure level is equivalent to the amount leaking from the test area. A second measurement is taken by doing the first test in reverse i.e. by de-pressurising the test area. The two readings are averaged to reduce error.

The computer then converts the flow and pressure readings into an Equivalent Leakage Area (ELA), or the total area of all the cracks, gaps and holes in the test area. The data generated is then processed using specifically designed computer software, in compliance with the National Fire Protection Association (NFPA) which predicts the period of time that the concentration will be held in the test area at a given height. This retention time can be further calculated for different heights.

The computer software has also been designed to be conservative with its predictions. The software produces the worst case scenario in which 50% of the cracks, gaps and holes in the test area are at a low level where heavier gas/air mixture will seep out and 50% are at a high level where lighter air will enter to displace it. This approach makes the results extremely reliable and means that any system which passes the room integrity test would have been virtually certain to pass a full discharge test.

Within an hour of the completed tests the computer produces a printout with full details of the input and test results, with a detailed report following in the post shortly afterwards. Failure is indicated if it takes less than ten minutes for the agent/air interface to drop below the minimum specified protected height. This minimum holding time of ten minutes is the period suggested by BS5306 Section 5.1 and the NFPA.

However, if the test area does fail to satisfy the requirements, a detailed survey is carried out making note of the leakage areas to allow remedial sealing works to be carried out.

 
 
Gielle Srl - Direzione ed Amministrazione 
Via Ferri Rocco 1001 Z.I. - 70022 Altamura (Ba) 
Tel +39 0803118998 - Fax + 39 0803101309
E-mail: info@fm200.biz 
Attivo tutti i giorni 24 ore su 24
 
 
Gielle Lombardia
S. Donato Milanese (Mi)
Via Bruno Buozzi, 37
e-mail: milano@gielle.it
  Gielle Piemonte
Grugliasco (To)
Via Bengasi, 25
e-mail: torino@gielle.it
  Gielle Lazio
Pomezia (Roma)
Via Orvieto, 132-134
e-mail: roma@gielle.it
 
 
 




2003 - Gielle Srl - all rights reserved - created by www.omnilink.it