fm 200 - fm-200 - fm200 - fm 200 fire suppression system - fm 200 fire protection - fm 200 fire extinguishers - enclosure fm200
Company | Headsquares | References | Quality | Contacts | Catalogues | Home
 

PRODUCTS & SERVICES
 » novec 1230 system
 » fire extinguishers
 » recovering halon
 » fire prevention systems
 » fire protection
 » door fan test
 » cold fire
 » motormax
 » fire barrier doors
 » signage and posters
 » training courses
 » servicing & maintenance
 » software & utility
CLEAN AGENTS
 » clean agent extinguisher
 » purchase clean agents
 » halon alternative
 » disposal cfc/hcfc/hfc
 » clean agents faq
MARINE FIRE SOLUTIONS
 » marine fire protection
 » ship halon phase out
 » ship halon alternative
 » replacing halon with
    novec 1230
 » replacing halon with
    fm-200
RESERVED TO
 » professionals
 » companies
 » public agencies
 » schools
DEEPENINGS
 » fire suppression system
 » fire extinguisher
 » fire safety
 » halon
 » inergen
 » hfc 23
 » hfc 227
 » fm-200
 » argon




FM-200 fire suppression systems: fm-200 gas extinguishing
 
FM-200® Fire Suppression agent was the first environmentally acceptable replacement for Halon 1301. FM-200® has zero ozone depleting potential, a low global warming potential and a short atmospheric lifetime. It is particularly useful where an environmentally acceptable agent is essential, where clean up of other media presents a problem, where weight versus suppression potential is a factor, where an electrically non-conductive medium is needed, and people compatibility an overriding factor.

FM-200® is a colourless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colourless, eclectically non-conductive vapour that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200® does not displace oxygen and therefore is safer for use in occupied spaces without fear of oxygen deprivation.

FM-200® is chosen to protect occupied areas such as computer rooms and now the fast expanding telecommunications market. Its low extinguishing concentration of seven percent by volume for Class A risks, its high level personnel safety and absence of toxicity makes it a very attractive option. Very little cylinder storage space is required which can be an important consideration in city centre sites where floor space is at its most expensive. 
 
 
     
 
Perhaps most in FM-200® favour though is the fact that it out performs the majority of other gaseous systems in terms of speed of reaction to fire. FM-200® is effective within 10 seconds of initial discharge. FM-200® has some significant advantages over other alternative agents. The rapid discharge time means that there is rapid knockdown of flame and the fire is rapidly extinguished. The amount of damage, toxicity effects and decomposition products of combustion are minimised. The safety percentage factor between the design concentration and toxicity levels is the largest margin of any fixed gaseous extinguishing systems and conformity exceeds that of Halon 1301. 

Benefits and Features
Fast & effective
No significant reduction in oxygen levels
Clean gaseous agent leaving no residue
Zero ozone depleting potential
Low global warming potential
Short atmospheric life span
Electronically non-conductive
Safe for use in fully occupied areas
Minimal storage requirement
Versatile range of containers, nozzle and ancillaries
Extensively tested, recognised and approved worldwide
Effective on site installation

Disadvantages 
Some Global Warming Potential 
Forms minimal decomposition products 
Higher agent cost

Typical applications are: 
Machinery 
Control and ventilation spaces 
Communications/computer rooms 
Control rooms, flammable liquid hazards
Computer Areas
Gas Turbines
Oil Industry Installations
Telecommunications
Power Generation
Shipping
Museums and Archives 

FM-200 fire suppression systems: more infos
 
In a typical system the extinguishing agent is typically stored in cylinders or spheres. It is delivered to distribution nozzles through a system piping network.

Critical to the functioning of the system is the fire detection and control network. Typically smoke detectors sense the presence of fire in the protected facility. The detection and control panel then sounds an alarm, shuts down air handlers, disconnects power from the protected equipment, and then releases agent into the protected area.

At Gielle Srl we make use of the Fike Intella-Scan Fire Detection Control Panel to control the release of agent. The Intella-Scan II control system uses both intelligent addressable analog sensors and centralized decision making to virtually eliminate false alarms and unwanted agent releases. The sensors report environmental conditions on a real-time basis to the control unit where the microcontroller makes the ultimate alarm decision. And the control panel is modular to allow you to add on to the system as your requirements change over time.

Assembling all the components together into a workable system optimized for your facility is the work of trained fire protection engineers. At Gielle Srl our engineering group will design your system, prepare shop drawings, flow and battery calculations, and provide you the hard data you need to rest assured in the confidence of a well designed fire protection system.
s available from Gielle Srl on all halocarbon and inert gas systems.

 
 
Gielle Srl - Administrative Headsquares 
Via Ferri Rocco 1001 Z.I. - 70022 Altamura (Ba) 
Tel +39 0803118998 - Fax + 39 0803101309
E-mail: info@fm200.biz 